Reply from numac on Dec 3 at 2:32 AM Hello, I tried this, it did not work properly, but I found a way to make it work. For that thank you. However, in this manner I just send the data from 1 counter to another, and i have to change also the counter in the IP02. Because I have over 500 counters this was not the answer I hoped for. I was hoping for an easy way to copy the counter in the whole from one place to another, but it's probably not possible. Regards John greoenendaal
| | | ---------------Original Message--------------- From: Vikas Sharma Sent: Friday, November 29, 2013 6:50 AM Subject: Copy Counters from a Functional Location to an Equipment Hi, To transfer counter from one measuring point to another (Functional location to Equipment or equipment to equipment), follow following steps Part 1 Step 1: Run tcode IK02. Step 2: At top left cornor, click on Additional data. Step 3: Tick on Transfer Supported. Step 4: Ok and Save. Part 2 Step 1: Create new measuring point for equipment through ik01. Step 2: Fill all the required data. Step 3: At top let corner, click on Additional data. Step 4: Click on "Assign Manually" Step 5: Fill Reading transfred from and duration as per our requirment. Step 6: Ok and Save measuring point. All the counters would be transfered from previous measuring point to new measuring point. NOTE: Charactersticts of previous and new measuring point should be same. Regards.. Vikas Sharma | | Reply to this email to post your response. __.____._ | _.____.__ |