Announcement:
wanna exchange links? contact me at sapchatroom@gmail.com.
Posted by
Admin at
Reply from Ajayvarmak on Jul 10 at 2:26 AM Hi, When you are running LSMW and system asked for partner profile. You have to setup your IDoc configuration in LSMW: 1) Enter the menu \Settings\IDoc Inbound Processing 2) Create a FILE port by clicking "Maintain Ports" 3) Create a logical system (LS) partner number by clicking "Maintain Partner Numbers" 4) Be sure your partner profile that you create is "Active" by clicking "Classification" 5) In the end click "Activate IDoc Inbound Processing" bottom. Run your LSMW again. This time it should run without any problem Regards, Ajay.
| | | ---------------Original Message--------------- From: maass1975 Sent: Tuesday, July 08, 2014 4:17 PM Subject: LSMW: Create a Partner Profile for Message Type 'PORDCR1' Hi Folks, Within LSMW, in process step "Start Generation IDOC", the next message is shown: Create a partner profile for message type 'PORDCR1' Message no. /SAPDMC/LSMW811 I'm functional so, not familiar with IDOC TCodes, If anyone has the step by step how to solve this issue, please share Thanks a lot! | | Reply to this email to post your response. __.____._ | _.____.__ |