Phillip,

Did you get a response to this inquiry? I would like to set up alerts for one specific job in the case that it fails. This is exactly the situation you have described.

The job runs on a satellite system and our alerts are generated through a solution manager that monitors specific MTE classes. I would like to set up different auto reactions for different jobs.

Thanks,
Judy.

---------------Original Message---------------
From: Phillip Wendell
Sent: Friday, May 21, 2010 11:17 AM
Subject: How to create an MTE class

I want to setup a job monitor that will alert a particular user with a central autoreaction when their job fails. I have done the following:

1. Added the job name in table ALBTCMON (using SM30)
2. Created a new monitor set in RZ20
3. Generated a new monitor under it and selected <new monitor> - <system name> - Background - Background Job Monitoring - <job name>

I then go into the monitor, select Properties at the job name level and see that the MTE class is set to Job_Monitoring_MO.

My problem is that when I setup an autoreaction I can set one up for Job_Monitoring_MO, but it does the same reaction for every monitor that uses that class. I need to either specify rules for just this monitor or I need to copy that MTE class and create a new one for each monitor.

Any help would be appreciated. Thanks,

Phillip

__.____._
Copyright © 2011 Toolbox.com and message author.

Toolbox.com 4343 N. Scottsdale Road Suite 280, Scottsdale, AZ 85251
Mark as helpful
View this online
  
Popular White Papers

In the Spotlight
Share Knowledge About SAP Scripting. Join the Discussion Group
_.____.__

0 comments:

Post a Comment

T r a n s l a t e to your language