Reply from Brent_Clark on Apr 30 at 8:00 AM
To move multiple equipment from one FLOC to another as long as the source and destination FLOC are the same, one can use CC04. You enter the destination FLOC first and enter. Click on the selection arrow at the top and enter the source FLOC. Select and move the equipment you want.

Regards
BRENT CLARK
Enterprise Asset Management SAP Business Process Leader

---------------Original Message---------------
From: Kayato
Sent: Wednesday, April 29, 2015 3:38 AM
Subject: SWAP Equipments (IE4N) Without Serial Number and Material, is It Possible?

Hi there, Sorry about the last post. It was a mistake.

Brent, by using the IE02, I'll have to perform 2 steps, right? each step for each equipment. There is not possible to do it all, at the same time, right?

Thanks in advance for your help.

 