Announcement:
wanna exchange links? contact me at sapchatroom@gmail.com.
Posted by
Admin at
Reply from D. Caddick on Jun 24 at 9:16 AM Hi Sergio, The ABAP short dump "TSV_TNEW_PAGE_ALLOC_FAILED" is an indication of lack of resources or the program select statements are too big, Go to Tx ST22 and review the complete short dump details. If this is a SAP standard program you will find some search terms and search for relevant SAP Notes. Regards
| | | ---------------Original Message--------------- From: Sergio Desormeaux Sent: Saturday, June 21, 2014 4:40 PM Subject: SCHEDULER_WATCH and MAX.RUNTIME parameters Hi all! I'm using RFC_READ_TABLE to extract UST12 table which hasmore than 12 million records and fails due timeout. This in an installation of a client that has the ECC version 5. Previously I solved this problem in ECC Version 6 adjusting parameters SCHEDULER_WATCH = 3600 and MAX.RUNTIME =1800 . The client tells me that these parameters do not exist in version 5. Could tell me which are the equivalent parameters for version 5? Many thanks in advance! Regards Sergio | | Reply to this email to post your response. __.____._ | In the Spotlight Become a blogger at Toolbox.com and share your expertise with the community. Start today. _.____.__ |