Announcement:
wanna exchange links? contact me at sapchatroom@gmail.com.
Posted by
Admin at
Hi Vidhyadhar,
Thanks for your reply. I could check again the repeat of the Dunning run for the customer after it has reached its final Dunning level and the Repeat of the Internal dunning notice was created.
I have selected a wrong customer earlier for one of the dunning runs. Also the problem with testing a Dunning run is we cannot have the results immediately. If the Dunning levels are 3 and to test some of the things we need to wait minimum 3 days to know clearly.
Regards, SNK.
| | | ---------------Original Message--------------- From: VidhyaDhar Sent: Friday, October 22, 2010 10:16 PM Subject: Dunning some questions Hi SNK
I can understand your predicament when the system does not spew out results after a carrying out a repeat dunning. There could be one or more reasons for such system behavior identification of which is rendered easier when we have a complete picture of the related dunning procedure. Dunning frequency and dunning interval form simply a part of the dunning procedure. For instance, it would be better to know how minimum amounts have been configured for each dunning level and a non-compliance to this could also result in a dunning without generation of a dunning notice. Dunning also depends on things like line item grace period ( applicable for first level dunning only ) and minimum amount in arrears ( at least one line item should comply with the terms of configuration ) for dunning to happen.
People have a tendency to recreate (with the same parameters) dunning proposals when a proposal fails to give a result. This could result in multiple proposals and parameters generated and left dangling. This could also prevent subsequent dunning. If this is the case, it would be better to delete such unused proposals and parameters.
Dunning Blocks ( of accounts and / line items ) ,if any, could also prevent further dunning.
Dunning Keys , defined if any, could also result in restrictive dunning that could never allow escalation of dunning levels.
Configuration of dunning procedure which permits only incremental changes to be printed could also be one of the reasons.
These are some of the possible reasons for a dunning procedure not resulting in a dunning notice
A complete analysis of the procedure helps in finding out the reasons for the inability of the system in creating a dunning notice.
May be you could carry out a detailed check how you have defined your dunning procedure. Did you check details of last dunning level and last dunned date in the customer master and the related line items?
Regards
VidhyaDhar
Regards
VidhyaDhar | | __.____._ Copyright © 2010 Toolbox.com and message author. Toolbox.com 4343 N. Scottsdale Road Suite 280, Scottsdale, AZ 85251 | | Related Content Most Popular White Papers In the Spotlight _.____.__ |