Dear Vamsi,
You can use calculated characteristics in the control indicators of X2, X3
& X4,
Set the same formula as you have mentioned in the control indicatiors of
MIC in the inspection plan.
While results recording, enter the value of X1 and get the values of X2,X3
& X4 calculated.
With Regards,
Burzis Muglai
Mobile # 91 9426406735

"qm_ittool via sap-log-qm" <sap-log-qm@group To s.ittoolbox.com> Burzis J Muglai/India/IBM@IBMIN cc 06/19/2009 09:26 AM Subject [sap-log-qm] Master inspection characterisitics Please respond to sap-log-qm@groups .ittoolbox.com

(Embedded image moved to file: pic04102.jpg) Hi All, One scenario related to the MIC, I have got 4 mic's X1, X2, X3, X4. In the inspection plan i need to maintain the Limits of the above mic's. the lower limit values of the X2 = 2.5X1, X3=0.8X, X4= 2.0X, where the value of X1=X. How to map this ? does anybody has any clue related to the same or faced a similar situation like this. thanks in advance Regards, vamsi