Reply from Junaid_Ahmad on Oct 1 at 1:26 AM Hello Snowvy! Thanks for the reply! We can reserve DIA W.P by giving value to the parameter :- rdisp/rfc_min_wait_dia_wp=1(default) that have to necessarily remain free for other users. This parameter is used to reserve a number of dialog work processes for Dailog mode. For example, If 10 dialog w.p. are configured for the instance(rdsip/wp_no_dia=10) and the parameter rdisp/rfc_min_wait_dia_wp=3 is set,parallel RFC's can occupy a maximum of 7 DIA W.P.3 DAI W.P. always remain free for dialog mode. But now the question is how we assign/restrict this free dialog w.p. to the specific user. Regards, JUNAID
| | | ---------------Original Message--------------- From: Junaid_Ahmad Sent: Tuesday, September 30, 2014 3:09 AM Subject: How to Limit the Max Dialog No That One User Can Use at the Same Time? Hello, Can we restrict Dialog work process according user wise and can we set the priority high or low? (For example, We can restrict the spool In su01 we can restrict the spool user wise by clicking on Out put immediately check box so is this possible to restrict Dialog w.p according to the user? Regards, JUNAID AHMAD | | Reply to this email to post your response. __.____._ | In the Spotlight Become a blogger at Toolbox.com and share your expertise with the community. Start today. _.____.__ |