Reply from JG-SAPHR on Nov 30 at 8:55 AM Time eval will not run from a previous date without a reason. Either you force it through date from/to sel.inputs or through PDC recal date. If the run is for simulation only as per sel input, when you run again later, it will still recalculate based on the same reasons. You can investigate as below: 1. Run infotype changes report for one/more such employee/s from a past date = the last PDC run date. 2. Display each IT 3 line. Check where PDC recalc date has been updated. If it has gone back, then check which infotype caused this and why. Usually it would be listed after the IT 3 line.
| | | ---------------Original Message--------------- From: bhakash Sent: Friday, November 28, 2014 8:43 AM Subject: Time Evaluation - start date issue Dear Experts. We gone live with time evaluation 20.10.2014. Live run done successfully for 20.10.2014 and PDC recalculation has been updated as 21.10.2014 in IT0003. While running for 21.10.2014 again its running from 20.10.2014(i.e., as per Earl.pers.rec.date) but not based on PDC recalculation date. Actually it should run only for 21.10.2014. Please help on the same. Thanks bharath | | Reply to this email to post your response. __.____._ | _.____.__ |