Reply from ERPel on Mar 16 at 9:18 AM Hi Wes, I am using the BAPI BAPI_OBJCL_CHANGE. I am not so convinced. There is still a small chance that another process is "stealing" my lock again when I released it. That's why I would like my update to fail but the respective LUW should be kept for another try later. So I don't need to deal with locks. Robert
| | | ---------------Original Message--------------- From: Wes Arey Sent: Friday, March 15, 2013 1:53 PM Subject: Asynchronous Update of Objects (Batches) Robert: You should be able to call the same enque function modules that the BAPI is using before calling the BAPI. I'd modify Pierre's suggestion only that in step 2 - attempt to lock using the appropriate enque FM(s) , if lock is granted then unlock and call the BAPI. As a note, you haven't told what BAPI you are calling. Help can be more specific if you are wes. | | Reply to this email to post your response. __.____._ | _.____.__ |